- ProductsLocation:Home > Products > AC Contactor > Thermal Relay
-
Item Nunber & Product Name:GTR2Prev:The First!Next:GTR2N
- Description
GTR2 Application GTR2 Series overload relays apply to circuit of AC 50Hz or 60Hz,rated voltage to below 660V and rated current 0.1A~93A for AC motor overload and open-phase protection during long time or intermittent long time service,which can also protect 3-phase serious imbalance and long starting time of motor or long time operation, can also be used for corresponding AC contactor for electromagnetic starter.
This product has innovative, elegant model and small installation area, functions such as temperature compensation,action indication,automatic and manual reset, stop with steady and reliable performance
Thermal relay can be combined/connected with contactor or installedseparately.
Standard: IEC 60947-4-1Tripping curve 1. Equilibrium running, 3 phase, start from cold state
2. Equilibrium running, 2 phase, start from cold state
3. Equilibrium running, 3 phase, after long period of
setting current (hot state)Technical Data Type GTR2-D13 GTR2-D23 GTR2-D33 Standard A IEC60947-4-1 IEC60947-4-1 IEC60947-4-1 Rated working current Ie V 25 36 96 Rated insulating voltage Ui 660 660 660 Phase failure protection function yes yes yes Automatic & manual reset yes yes yes Temperature compensation yes yes yes Releasing indicator yes yes yes Test & stop pushbutton yes yes yes Auxiliary contacts Rated current AC-15 230V A 2.73 2.73 2.73 AC-15 380V A 1.58 1.58 1.58 DC-13 230V A 0.2 0.2 0.2 Ambient air temperature. ℃ -5 ~ +40 -5 ~ +40 -5 ~ +40 Altitude max meter 2000 2000 2000 Pollution grade 3 3 3 Installation category 3 3 3 Mounting type Independent yes yes yes Plug-in yes yes yes Action Characteristics Overload Protecion Item No. Setting current multiple Action time Start condition Ambient air temperature 1 1.05 ≥ 2h Cold state start 2 1.2 <2h After test item 1 20 ℃ ±5 ℃ 3 1.5 <2min After test item 1 4 7.2 2s Cold state start Phase failure protection Item No. Setting current multiple Action time Start condition Ambient air temperature Any two phase The third phase 5 1.0 0.9 ≥ 2h Cold state start 20°C±5°C 6 1.15 0 <2h After test item 5 Ref.
Model Setting Range(A) For Contactor Case Qty.(Pcs) GTR2-25-D1301 0.10-0.16 GTC1-D09 100 GTR2-25-D1302 0.16-0.25 GTC1-D09 100 GTR2-25-D1303 0.25-0.40 GTC1-D09 100 GTR2-25-D1304 0.40-0.63 GTC1-D09 100 GTR2-25-D1305 0.63-1 GTC1-D09 100 GTR2-25-D1306 1-1.6 GTC1-D09 100 GTR2-25-D1307 1.6-2.5 GTC1-D09 100 GTR2-25-D1308 2.5-4 GTC1-D09 100 GTR2-25-D1310 4-6 GTC1-D09 100 GTR2-25-D1312 5.5-8 GTC1-D09 100 GTR2-25-D1314 7-10 GTC1-D12 100 GTR2-25-D1316 9-13 GTC1-D12 100 GTR2-25-D1321 12-18 GTC1-D18 100 GTR2-25-D1322 17-25 GTC1-D25 100 DR2-36-D2353 23-32 GTC1-D32 75 GTR2-36-D2355 30-40 GTC1-D32 75 GTR2-93-D3322 17-25 GTC1-D40 50 GTR2-93-D3353 23-32 GTC1-D40 50 GTR2-93-D3355 30-40 GTC1-D40 50 GTR2-93-D3357 37-50 GTC1-D50 50 GTR2-93-D3359 48-65 GTC1-D65 50 GTR2-93-D3361 55-70 GTC1-D80 50 GTR2-93-D3363 63-80 GTC1-D80 50 GTR2-93-D3365 80-93 GTC1-D95 50 Installation Dimensions (see Fig 1-Fig 3)
Operation Instruction (see Figure 4)Matched relay Order code GTR2-25 LA7-D1064 GTR2-36 LA7-D2064 GTR2-93 LA7-D3064